당사 제품 비교
비교할 제품
Mechanical
Standard profile PC card
'C2C-LINK' on printed circuit board:
6-pin 2-row 0.1" pitch pin header with shrouding
Card-to-card link
PCB L x H: 44 mm x 101 mm, 1.7 in x 4.0 in
Cable lenght: 200 mm, 7.9 in
Net weight: 81 g [2.9 oz]
Gross weight: 184 g [6.5 oz]
C2C-Link
Accurate synchronization of the trigger and the start-of-exposure of multiple grabber-controlled area-scan cameras.
Accurate synchronization of the start-of-cycle, start-of-scan and end-of-scan of multiple grabber-controlled line-scan cameras.
C2C-Link synchronizes cameras connected to:
the same card
to different cards in the same PC (requires an accessory cable such as the "3303 C2C-Link Ribbon Cable" or a custom-made C2C-Link cable)
to different cards in different PCs (requires one "1636 InterPC C2C-Link Adapter" for each PC and one RJ 45 CAT 5 STP straight LAN cable for each adapter but the last one)
Maximum distance:
120 cm inside a PC
1200 m cumulated adapter to adapter cable length
Maximum trigger rate:
2.5 MHz for configurations using a single PC, or up to 10 PCs and 100 m total C2C-Link cable length
200 kHz for configurations up to 32 PCs and 1200m total C2C-Link cable length
Trigger propagation delay from master to slave devices:
Less than 10 ns for cameras on the same card or on different cards in the same PC
Less than 265 ns for cameras on different cards in different PCs (3 PCs and 40m total C2C-Link cable length)
Certifications
EN 55032:2015 / CISPR 32:2012 Class B
FCC 47 Part 15 Class B
EN 55024:2010 / CISPR 24:2010
EN 55035:2017 / CISPR 35:2016
EN 61000-4-2:2009
EN 61000-4-3:2006
EN 61000-4-4:2004
EN 61000-4-6:2014
Korean Radio Waves Act, Article 58-2, Clause 3
PCB compliant with UL 94 V-0
European Union Directive 2015/863 (ROHS3)
European Union Regulation 1907/2006
Must be disposed of separately from normal household waste and must be recycled according to local regulations
Ordering Information
PC1636 InterPC C2C-Link Adapter
200 mm 26-way Ribbon Cable
PC3303 - C2C-Link Ribbon Cable