HD26F I/O Extension Module - TTL-CMOS5V-RS422

汎用I/O拡張機能モジュール

概要
  • 高度な設定が可能
  • 最大20 TTL I/Oまたは10 RS-422 I/O
  • 高速TTL I/O: 最大1 MHz
  • 超高速RS-422 I/O: 最大10 MHz
  • CMOS 5V出力レベル
  • Coaxlink Octo、Coaxlink Mono CXP-12、Coaxlink Duo CXP-12、Coaxlink Quad CXP-12、Coaxlink Quad CXP-12 JPEG、 Coaxlink QSFP+に対応



比較 販売店


Mechanical
Format Standard profile PC card
Connectors
  • ' EXTERNAL I/O' on bracket:
    • 26-pin 3-row high-density female sub-D connector
    • I/O lines and power output
  • 'INTERNAL I/O' on PCB:
    • 26-pin 2-row 0.1" pitch IDC female connector
    • I/O lines and power output
  • 'I/O EXTENSION' on PCB
    • 26-pin 2-row 0.05" pitch IDC female connector
    • I/O control, data and power
LED indicators
  • "ACTIVITY LED's" on bracket
    • Two bicolor red and green LED's
    • Activity on input and output ports respectively
  • "STATUS LED" on PCB
    • Bicolor red and green LED's
    • Power status
    • I/O EXTENSION link status
Dimensions
  • PCB L x H: 80 mm x 74 mm , 3.15 in x 2.9 in
  • Cable length: 150 mm, 5.9 in
General Purpose Inputs and Outputs
Number of lines Configurable mix of 4 types of I/O ports
  • Up to 20 TTL inputs
  • Up to 20 5V CMOS outputs
  • Up to 10 RS-422 inputs
  • Up to 10 RS-422 outputs
Usage
  • Any I/O input lines can be used by any LIN tool of the I/O Toolbox
  • Selected pairs of I/O input lines can be used by any QDC tool of the I/O toolbox to decode A/B signals of a motion encoder
Electrical specifications
  • TTL inputs: High-speed 5V-compliant TTL inputs compatible with totem-pole LVTTL, TTL, 5V CMOS drivers
  • 5V CMOS outputs: High-speed 5 V CMOS outputs compatible with 5V CMOS and 5V TTL receivers
  • RS-422 inputs: High-speed differential inputs compatible with ANSI/EIA/TIA-422 differential line drivers
  • RS-422 outputs: High-speed differential inputs compatible with ANSI/EIA/TIA-422 differential line receivers
Power output Non-isolated, +12V, 1A delivered by the Coaxlink card though the I/O EXTENSION cable
Electrical
Supply voltage 12 V DC delivered by the Coaxlink card through the I/O EXTENSION cable
Power consumption Max. 5 W (excluding 12 V POWER output)
Environmental conditions
Operating ambient air temperature 0 °C to +55 °C / +32 °F to +131 °F
Operating ambient air humidity 10% to 90% RH non-condensing
Storage ambient air temperature -20 °C to +70 °C/ -4 °F to +158 °F
Storage ambient air humidity 10% to 90% RH non-condensing
Certifications
EMC - Immunity
  • EN 55024:2010 / CISPR 24:2010
  • EN 55035:2017 / CISPR 35:2016
  • EN 61000-4-2:2009
  • EN 61000-4-3:2006
  • EN 61000-4-4:2004
  • EN 61000-4-6:2014
KC Certification Korean Radio Waves Act, Article 58-2, Clause 3
RoHS European Union Directive 2015/863 (ROHS3)
REACH European Union Regulation 1907/2006
WEEE Must be disposed of separately from normal household waste and must be recycled according to local regulations
Ordering Information
Product code - Description